Operating mode | Holding and braking: non-adjustable spring,Release: compressed air |
Function type | Static holding,Dynamic braking |
Locking unit | Clamping jaw lock |
Piston diameter | 100 mm |
suitable piston rod diameter | 25 mm |
Piston diameter | 100 mm |
Sealing material | Nitrile butadiene rubber |
Scraper | Nitrile butadiene rubber |
Nominal flow Qn | 700 l/min |
Compressed air connection | G 1/8 |
Version | Clamping jaw lock |
Function | Static holding Dynamic braking |
Release pressure | 4 … 10 bar |
Ambient temperature min./max. | -25 … 80 °C |
Medium temperature min./max. | -25 … 80 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 mg/m³ |
Weight | See table |
The maximum ambient and medium temperature is + 70 °C for the dynamic braking function. Note:Before pressurizing the locking unit, make sure that there is a balance of forces at the piston on the drive cylinder. Please see the operating instructions for further safety-relevant information. The locking unit can be used in controls with a max. performance level e in accordance with DIN EN ISO 13849-1 (“basic and well-tried safety principles”). For applications in category 2 to 4 controls, additional control measures according to DIN EN ISO 13849-1 are required. The locking unit can be used as an individual component or pre-mounted on a cylinder.. Scope of delivery: LU6, each with 4 flange nuts, washers, and tie rods For technical reasons, formulas and sample calculations have been moved to the MediaCentre (link to operating instructions). |
Material |
---|
Housing | Aluminum, anodized |
Seal | Nitrile butadiene rubber |
Scraper | Nitrile butadiene rubber |