Return type | With air spring return |
Switching principle | 5/2 |
Version | Diaphragm poppet valve |
Housing | Polyoxymethylene,Polyarylamide |
Sealing material | Acrylonitrile butadiene rubber |
UL (Underwriters Laboratories) | |
Connector standard | EN 175301-803:2006 |
Protection class | IP65 |
Port size | EN 175301-803, form A |
Type | Plug |
Nominal flow Qn | 700 l/min |
Compressed air connection input | 3/8? |
Compressed air connection output | 3/8? |
Operational voltage AC at 50 Hz | 110 V |
Operational voltage AC at 60 Hz | 110 V |
Activation | Electrically |
Version | Diaphragm poppet valve |
Activation | Electrically |
Pilot | Internal |
Sealing principle | Soft sealing |
Blocking principle | Plate principle Single base plate principle |
Certificates | UL (Underwriters Laboratories) |
Working pressure min./max. | 1,5 … 10 bar |
Ambient temperature min./max. | -15 … 50 °C |
Medium temperature min./max. | -15 … 50 °C |
Medium | Compressed air |
Max. particle size | 50 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow Qn | 700 l/min |
Connector standard | EN 175301-803:2006 |
Protection class with connection | IP65 |
Reverse polarity protection | Protected against polarity reversal |
Compatibility index | 14 |
Duty cycle | 100 % |
Typ. switch-on time | 40 ms |
Typ. switch-off time | 40 ms |
Mounting on manifold strip | PRS strip |
Weight | 0,505 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
UL recognized solenoid coils with cURus mark |
Material |
---|
Housing | Polyoxymethylene Polyoxymethylene Polyarylamide |
Seals | Acrylonitrile butadiene rubber |