Version | Poppet valve |
Housing | Polyamide |
Sealing material | Acrylonitrile butadiene rubber |
Qn 1?2 | 4500 l/min |
Qn 2?3 | 3200 l/min |
Nominal flow Qn | 4500 l/min |
Compressed air connection input | G 1/2 |
Compressed air connection output | G 1/2 |
Version | Poppet valve, Can be assembled into blocks |
Parts | 3/2-directional valve, electrically operated |
Nominal flow | 4500 l/min |
Nominal flow 1 ? 2 | 4500 l/min |
Nominal flow 2 ? 3 | 3200 l/min |
Working pressure min./max. | See table |
Medium | Compressed air Neutral gases |
Medium temperature min./max. | -10 … 50 °C |
Ambient temperature min./max. | -10 … 50 °C |
Sealing principle | Soft sealing |
Max. particle size | 25 µm |
Weight | 0,459 kg |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about the vertical axis. Please see the operating instructions for further details. Can be used in circuits with increased efficiency. An ST6 sensor (contactless) is used to detect the switching position in the non-actuated state (position: exhaust). The sensor signal is visible on the front of the cover. |
Material |
---|
Housing | Polyamide |
Front plate | Acrylonitrile butadiene styrene |
Seals | Acrylonitrile butadiene rubber |
Threaded bushing | Die cast zinc |