Functional principle | double-acting |
Cushioning | pneumatically |
adjustable | |
Magnetic piston | with magnetic piston |
Piston diameter | 40 mm |
Piston rod thread | M12x1,25 |
Standardization | ISO 15552 |
Stroke | 100 mm |
Sealing material | Polyurethane |
Scraper | Polyurethane |
ATEX optional | |
Compressed air connection | G 1/4 |
Compressed air connection type | Internal thread |
Standards | ISO 15552 |
Certificates | ATEX optional |
Compressed air connection | Internal thread |
Working pressure min./max. | 1,5 … 10 bar |
Ambient temperature min./max. | -20 … 80 °C |
Medium temperature min./max. | -20 … 80 °C |
Medium | Compressed air |
Max. particle size | 50 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Pressure for determining piston forces | 6.3 bar |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
ATEX-certified cylinders with identification II 2G Ex h IIB T4 Gb / II 2D Ex h IIIB T135°C Db_X can be generated in the Internet configurator. The operating temperature range for ATEX-certified cylinders is -20 °C … 50 °C. |
Material |
---|
Cylinder tube | Aluminum, anodized |
Piston rod | Stainless steel |
Front cover | Die-cast aluminum |
End cover | Die-cast aluminum |
Seal | Polyurethane |
Nut for piston rod | Steel, galvanized |
Scraper | Polyurethane |
Tie-rods | Stainless steel Steel, galvanized |
See table for additional data on materials. |