Actuating control | single solenoid |
Housing | Polyamide,Polyoxymethylene |
Protection class | IP65 |
Compressed air connection input | Ø 3/8 |
Compressed air connection output | Base plate |
DC operating voltage | 24 V |
Activation | Electrically |
Activation | Electrically |
Working pressure min./max. | 0 … 8 bar |
Ambient temperature min./max. | 5 … 50 °C |
Medium temperature min./max. | 5 … 50 °C |
Medium | Compressed air |
Max. particle size | 40 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Protection class with connection | IP65 |
Duty cycle | 100 % |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | Polyamide Polyoxymethylene |