Version | Poppet valve |
Logic function | AND |
Housing | Polyamide |
Sealing material | Acrylonitrile butadiene rubber |
Nominal flow Qn | 80 l/min |
Compressed air connection input | Ø 4 |
Compressed air connection output | Ø 4 |
Version | Poppet valve |
Sealing principle | Soft sealing |
Logic function | AND |
Working pressure min./max. | 1 … 10 bar |
Ambient temperature min./max. | 0 … 80 °C |
Medium temperature min./max. | 0 … 80 °C |
Medium | Compressed air |
Max. particle size | 1 µm |
Oil content of compressed air | 0 … 1 mg/m³ |
Weight | See table |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | Polyamide |
Seals | Acrylonitrile butadiene rubber |