Housing | Polyamide |
Sealing material | Acrylonitrile butadiene rubber |
Number of wires | 3-pin |
Port size | M8x1 |
DC operating voltage | 24 V |
Activation | Electrically |
Activation | Electrically |
Control pressure min./max. | 3 … 8 bar |
Ambient temperature min./max. | 5 … 50 °C |
Medium temperature min./max. | 5 … 50 °C |
Duty cycle | 100 % |
mounting screws | Hexalobular socket (TORX) ISO 10664-10 |
Mounting screw tightening torque | 0,9 Nm |
Tightening torque tolerance | ±0,1 mT |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | Polyamide |
Seals | Acrylonitrile butadiene rubber |