Return type | With spring return |
Version | Poppet valve |
Sealing material | Fluorocaoutchouc |
Port size | EN 175301-803, form A |
Type | Plug |
Qn 1?2 | 140 l/min |
Qn 2?3 | 130 l/min |
Operational voltage AC at 50 Hz | 110 V |
Operational voltage AC at 60 Hz | 110 V |
Activation | Electrically |
Version | Poppet valve |
Activation | Electrically |
Sealing principle | Soft sealing |
Working pressure min./max. | 0 … 10 bar |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air |
Nominal flow 1 ? 2 | See table |
Nominal flow 2 ? 3 | 130 l/min |
Duty cycle | 100 % |
mounting screws | M4 |
Tightening torque tolerance | +0,3 |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Seals | Fluorocaoutchouc |