Parts | Microfilter |
Condensate drain | fully automatic, open without pressure |
filter porosity | 0.01 µm |
inspection glass | with window |
Housing | Polyamide |
Reservoir | Die cast zinc |
Sealing material | Acrylonitrile butadiene rubber |
suitable for ATEX | |
Nominal flow Qn | 1600 l/min |
Compressed air connection | G 3/4 |
Version | Microfilter, Can be assembled into blocks |
Parts | Microfilter |
Mounting orientation | vertical |
Certificates | suitable for ATEX |
Working pressure min./max. | See table |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air Neutral gases |
Filter reservoir volume | 87 cm³ |
Filter element | exchangeable |
filter porosity | 0,01 µm |
Condensate drain | See table |
contamination display | integrated |
Weight | See table |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . Note: Polycarbonate reservoirs are susceptible to solvents, supplementary information can be found at “Customer information”. Suitable for use in Ex zones 1, 2, 21, 22. A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about the vertical axis. Please see the operating instructions for further details. |
|
Recommended pre-filtering | 0,3 µm |
Max. achievable compressed air class acc. to ISO 8573-1:2010 | 1 : – : 2 |
Material |
---|
Housing | Polyamide |
Front plate | Acrylonitrile butadiene styrene |
Seals | Acrylonitrile butadiene rubber |
Threaded bushing | Die cast zinc |
Reservoir | Polycarbonate Die cast zinc |
Protective guard | Polyamide |
Filter insert | Borosilicate glass fiber |