Number of valve positions | 4 |
Subbase | Aluminum |
Compressed air connection input | M5 |
Compressed air connection output | M3 |
Version | Single plug-in wiring |
Working pressure min./max. | 0 … 8 bar |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air |
Grid dimension | 11 mm |
Direction of pneumatic port (2,4) | On the side |
Exhaust (3,5) | With directional exhaust (3/5) |
Mounting screw | M1.6 |
Weight | See table |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Base plate | Aluminum |