Operating mode | Hold: adjustable spring force,Release: compressed air |
Function type | Clamp with eccentric tappet |
suitable piston rod diameter | 25 mm |
Piston diameter | 80,100 mm |
Compressed air connection | G 1/8 |
Function | Clamp with eccentric tappet |
Release pressure | 2 … 8 bar |
Ambient temperature min./max. | -20 … 80 °C |
Medium temperature min./max. | -20 … 80 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Weight | See table |
Warning:The Locking unit may not be used for the following applications:- for dynamic holding- in or as safety equipment Locking unit may only be unlocked when turned off. Note:The minimum release pressure is >= the working pressure of the cylinder!The holding force is dependent on the set spring force |
Material |
---|
Housing | Aluminum, anodized |
Cap | Die-cast aluminum |