Air supply | right |
Version | Poppet valve |
Housing | Polyamide |
Sealing material | Acrylonitrile butadiene rubber |
Qn 1?2 | 2000 l/min |
Nominal flow Qn | 2000 l/min |
Compressed air connection input | G 1/4 |
Compressed air connection output | G 1/4 |
Version | Poppet valve, Can be assembled into blocks |
Sealing principle | Soft sealing |
Working pressure min./max. | 0 … 16 bar |
Control pressure min./max. | 2,5 … 16 bar |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air Neutral gases |
Max. particle size | 40 µm |
Weight | 0,134 kg |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . Do not position filling valves or filling units upstream of open consumers, such as nozzles, air barriers, air curtains, since these may prevent through connection of components. The filling valve builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a recommissioning after a mains pressure failure or avoids emergency OFF switching. This allows dangerous abrupt cylinder motions to be avoided. |
Material |
---|
Housing | Polyamide |
Front plate | Acrylonitrile butadiene styrene |
Seals | Acrylonitrile butadiene rubber |
Threaded bushing | Die cast zinc |