Version | Poppet valve |
Housing | Polyamide |
Sealing material | Acrylonitrile butadiene rubber |
Nominal flow Qn | 4500 l/min |
Compressed air connection input | G 3/8 |
Compressed air connection output | G 3/8 |
Version | Poppet valve, Can be assembled into blocks |
Sealing principle | Soft sealing |
Working pressure min./max. | 2,5 … 16 bar |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air Neutral gases |
Max. particle size | 40 µm |
Weight | 0,43 kg |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The filling valve builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a recommissioning after a mains pressure failure or avoids emergency OFF switching. This allows dangerous abrupt cylinder motions to be avoided. Adjustable filling time and change-over pressure. Do not position filling valves or filling units upstream of open consumers, such as nozzles, air barriers, air curtains, since these may prevent through connection of components. A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about the vertical axis. Please see the operating instructions for further details. |
Material |
---|
Housing | Polyamide |
Front plate | Acrylonitrile butadiene styrene |
Seals | Acrylonitrile butadiene rubber |
Threaded bushing | Die cast zinc |