Housing | Polyamide |
Sealing material | Nitrile butadiene rubber |
For series | AV03-EP |
Type | Base plate for pressure zone control for fieldbus connection |
Working pressure min./max. | 0 … 11 bar |
Ambient temperature min./max. | -10 … 60 °C |
Medium | Compressed air |
Depending on the selected base plate, you can either use the pressure regulator as a pressure zone control or single pressure control. When using polyurethane tubing, we recommend using additional stiffener sleeves. For push-in fittings, only use plug accessories made of plastic (polyamide) from our catalog. After three I/O modules or 8 valves, mount a retaining bracket (R412018339) to fasten the entire unit to the mounting surface. |
Material |
---|
Housing | Polyamide |
Seals | Nitrile butadiene rubber |