Housing | Die-cast aluminum,Steel |
Sealing material | Hydrogenated acrylonitrile butadiene rubber |
CE declaration of conformity | |
Protection class | IP65 |
Port size | ISO 15217, form C |
Type | Plug |
Nominal flow Qn | 1000 l/min |
Hysteresis | < 0.06 bar |
Compressed air connection input | G 1/4 |
Compressed air connection output | G 1/4 |
DC operating voltage | 24 V |
Version | Poppet valve |
Mounting orientation | ? = 0-90° ? = 0-90° |
Certificates | CE declaration of conformity |
Working pressure max | 11 bar |
Ambient temperature min./max. | 0 … 70 °C |
Medium temperature min./max. | 0 … 70 °C |
Compressed air connection input | G 1/4 |
Compressed air connection output | G 1/4 |
Compressed air connection, exhaust | G 1/4 |
Medium | Compressed air |
Max. particle size | 50 µm |
Oil content of compressed air | 0 … 1 mg/m³ |
Nominal flow Qn | 1000 l/min |
Control | Analog |
DC operating voltage | 24 V |
Voltage tolerance DC | -20% / +20% |
Hysteresis | < 0.06 bar |
Permissible ripple | 5% |
Protection class | IP65 |
Weight | 1,1 kg |
Nominal flow Qn with working pressure 7 bar , with secondary pressure 6 bar and ?p = 0.2 bar |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
With oil-free, dry air, other installation positions are possible on request. The protection class is only ensured when the plug is mounted properly. For detailed information, see operating instructions. |
Material |
---|
Housing | Die-cast aluminum Steel |
Seals | Hydrogenated acrylonitrile butadiene rubber |