Number of valve positions | 1 |
Sealing material | Nitrile rubber |
Subbase | Aluminum |
Nominal flow Qn | 1400 l/min |
Compressed air connection input | G 1/2 |
Compressed air connection output | Ø 10 |
Type | Base plate for a single or double solenoid valve |
Nominal flow Qn | 1400 l/min |
Working pressure min./max. | -0,9 … 10 bar |
Control pressure min./max. | 2,5 … 10 bar |
Ambient temperature min./max. | 0 … 50 °C |
Medium temperature min./max. | 0 … 50 °C |
Medium | Compressed air |
Number of valve positions max. | 1 |
Grid dimension | 19,8 mm |
Exhaust (3,5) | With directional exhaust (3/5) |
Exhaust type | Ports separated |
Tightening torque for mounting screws | 1,1 Nm |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
The internal and external pneumatic pilots can be adjusted using the change-over plate on the left end plate. For internal pilot, working pressure is limited to 2.5 bar … 10 bar . |
Material |
---|
Base plate | Aluminum |
push-in fitting | Brass, nickel-plated |