Standardization | ISO 15407-1 |
Number of valve positions | 1 |
Frame size | 26 mm |
Sealing material | Acrylonitrile butadiene rubber |
Subbase | Polyamide fiber-glass reinforced |
Standards | ISO 15407-1 |
Compressed air connection | according to ISO 15407-1 |
Working pressure min./max. | -0,95 … 16 bar |
Ambient temperature min./max. | -15 … 50 °C |
Medium temperature min./max. | -15 … 50 °C |
Medium | Compressed air |
Number of valve positions max. | 1 |
Grid dimension | 27 mm |
Mounting screw | with hexagon socket |
Tightening torque for mounting screws | 2,5 Nm |
Weight | 0,088 kg |
An example configuration is illustrated. The delivered product may thus deviate from the illustration. |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
I/O functionality by combining with contact bridge kit for additional inputs/outputs |
Material |
---|
Base plate | Polyamide fiber-glass reinforced |
Seal | Acrylonitrile butadiene rubber |