Housing | Polyamide fiber-glass reinforced |
Sealing material | Nitrile butadiene rubber |
For series | ES05 |
Type | double solenoid |
Working pressure min./max. | 0 … 8 bar |
Control pressure min./max. | 3 … 8 bar |
Ambient temperature min./max. | 5 … 50 °C |
Medium temperature min./max. | 5 … 50 °C |
Medium | Compressed air |
Max. particle size | 40 µm |
Oil content of compressed air | 0 … 25 mg/m³ |
Tightening torque for mounting screws | 0,9 Nm |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
For use in conjunction with end plate kit with D-Sub |
Material |
---|
Housing | Polyamide fiber-glass reinforced |
Seal | Nitrile butadiene rubber |