Standardization | ISO 15407-2 |
Accessory type | type C |
Number of valve positions | 2 |
Frame size | 26 mm |
Sealing material | Acrylonitrile butadiene rubber |
Subbase | Aluminum |
For series | CD01-PI |
Type | Base plate for two single or double solenoid valves |
Standards | ISO 15407-2 |
Compressed air connection | according to ISO 15407-2 |
Working pressure min./max. | -0,95 … 16 bar |
Ambient temperature min./max. | -15 … 50 °C |
Medium temperature min./max. | -5 … 50 °C |
Medium | Compressed air |
Number of valve positions max. | 2 |
Grid dimension | 54 mm |
Exhaust type | Ports separated |
Mounting screw | with hexagon socket |
Tightening torque for mounting screws | 5 Nm |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Base plate | Aluminum |
Seal | Acrylonitrile butadiene rubber |