Actuating control | double solenoid |
Switching principle | 5/3 |
Version | Spool valve, positive overlapping |
Housing | Polyamide fiber-glass reinforced |
Sealing material | Acrylonitrile butadiene rubber,Hydrogenated nitrile butadiene rubber |
Connector standard | ISO 15217 |
Protection class | IP65 |
Port size | ISO 15217, form C |
Type | Plug |
Nominal flow Qn | 1300 l/min |
Compressed air connection input | G 1/4 |
Compressed air connection output | G 1/4 |
DC operating voltage | 24 V |
Activation | Electrically |
Version | Spool valve, positive overlapping |
Activation | Electrically |
Pilot | Internal |
Sealing principle | Soft sealing |
Working pressure min./max. | 3 … 10 bar |
Control pressure min./max. | 3 … 10 bar |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow Qn | 1300 l/min |
Connector standard | ISO 15217 |
Protection class with connection | IP65 |
Duty cycle | 100 % |
Typ. switch-on time | 12 ms |
Typ. switch-off time | 13 ms |
Mounting on manifold strip | P-strip |
Mounting screw tightening torque | 2,5 Nm |
Weight | 0,278 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | Polyamide fiber-glass reinforced |
Seals | Acrylonitrile butadiene rubber Hydrogenated nitrile butadiene rubber |
Front plate | Polyamide fiber-glass reinforced |
Threaded bushing | Brass Die cast zinc, nickel-plated chrome-plated |