Standardization | ISO 15407-1 |
Frame size | 26 mm |
Actuating control | double solenoid |
Switching principle | 5/3 |
Version | Spool valve, positive overlapping |
Housing | Polyamide,Polyoxymethylene |
Sealing material | Acrylonitrile butadiene rubber |
Free of substances that impair surface wetting in the coating process | |
Protection class | IP65 |
Port size | ISO 15407-2 |
Type | Plug |
Qn 1?2 | 650 l/min |
Qn 2?3 | 650 l/min |
Nominal flow Qn | 650 l/min |
Compressed air connection input | Base plate ISO 15407 |
Compressed air connection output | Base plate ISO 15407 |
DC operating voltage | 24 V |
Version | Spool valve, positive overlapping |
Pilot | External |
Sealing principle | Soft sealing |
Connection type | Plate connection |
Certificates | Free of substances that impair surface wetting in the coating process |
Working pressure min./max. | -0,95 … 16 bar |
Control pressure min./max. | 3 … 10 bar |
Ambient temperature min./max. | -15 … 50 °C |
Medium temperature min./max. | -15 … 50 °C |
Medium | Compressed air |
Max. particle size | 50 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow Qn | 650 l/min |
Protection class with connection | IP65 |
Protective circuit | 43 V bi-directional |
LED status display | Yellow |
Duty cycle | 100 % |
Typ. switch-on time | 24 ms |
Typ. switch-off time | 49 ms |
Mounting screw | M4 with hexagon socket |
Mounting screw tightening torque | 2,5 Nm |
Weight | 0,3 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Housing | Polyamide Polyoxymethylene |
Seals | Acrylonitrile butadiene rubber |