Actuating control | double solenoid – dominating |
Version | Spool valve, positive overlapping |
Housing | Polyamide fiber-glass reinforced |
Sealing material | Acrylonitrile butadiene rubber |
Nominal flow Qn | 1500 l/min |
Compressed air connection input | G 1/4 |
Compressed air connection output | G 1/4 |
Activation | pneumatically |
Version | Spool valve, positive overlapping |
Activation | pneumatically |
Pilot | External |
Sealing principle | Soft sealing |
Blocking principle | Plate principle |
Flow rate value | 1500 l/min |
Working pressure min./max. | See table |
Control pressure min./max. | See table |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 … 1 mg/m³ |
Rail mounting DIN EN 60715 | TH35 x 15 |
Weight | 0,159 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | Polyamide fiber-glass reinforced |
Seals | Acrylonitrile butadiene rubber |
Front plate | Polyamide fiber-glass reinforced |
Threaded bushing | Brass Die cast zinc, chrome-plated nickel-plated |