Standardization | ISO 5599-1 |
Frame size | ISO 2 |
Version | Spool valve, positive overlapping |
Housing | Polyamide |
Sealing material | Acrylonitrile butadiene rubber |
Nominal flow Qn | 2500 l/min |
Compressed air connection input | Base plate ISO 5599-1 |
Compressed air connection output | Base plate ISO 5599-1 |
Version | Spool valve, positive overlapping |
Pilot | External |
Blocking principle | Single base plate principle |
Sealing principle | Soft sealing |
Connection type | Plate connection |
Standards | ISO 5599-1, ISO 2 |
Nominal flow Qn | 2500 l/min |
Compressed air connection | Base plate ISO 5599-1 |
version pneumatic port | Base plate ISO 5599-1 |
Working pressure min./max. | -0,9 … 10 bar |
Control pressure min./max. | See table |
Ambient temperature min./max. | 0 … 80 °C |
Medium temperature min./max. | 0 … 80 °C |
Medium | Compressed air Class 5-4-4 class 6-4-3 |
Max. particle size | 5 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Mounting screw | M6 with hexagon socket |
Mounting screw tightening torque | 4 Nm |
Weight | See table |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Housing | Polyamide |
Seals | Acrylonitrile butadiene rubber |
Front plate | Polyamide |