Standardization | ISO 5599-1 |
Frame size | ISO 1 |
Actuating control | single solenoid |
Return type | With spring return |
Switching principle | 5/2 |
Version | Spool valve, positive overlapping |
Housing | Polyamide,Aluminum |
Sealing material | Acrylonitrile butadiene rubber |
Protection class | IP65 |
Nominal flow Qn | 1060 l/min |
Compressed air connection input | Base plate DIN ISO 5599 size 1 |
Compressed air connection output | Base plate DIN ISO 5599 size 1 |
Version | Spool valve, positive overlapping |
Sealing principle | Soft sealing |
Blocking principle | Single base plate principle |
Connection type | Plate connection |
Standards | ISO 5599-1, ISO 1 |
Working pressure min./max. | See table |
Control pressure min./max. | 3 … 10 bar |
Ambient temperature min./max. | 0 … 50 °C |
Medium temperature min./max. | 0 … 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 … 0,01 mg/m³ |
Nominal flow Qn | 1060 l/min |
Protection class with connection | IP65 |
Compatibility index | 15 |
Duty cycle | 100 % |
Switch-on time max. | 18 ms |
Switch-off time max. | 40 ms |
Version sensor | electronic PNP, with LED |
Sensor connection | Plug, M8, 3-pin, with knurled screw |
Operating voltage sensor DC min./max. | 10 … 30 V DC |
Voltage drop sensor U at Imax | ? 2,5 V |
Vibration resistance sensor | 10 – 55 Hz, 1 mm |
Shock resistance sensor | 30 g / 11 ms |
Cable length sensor | 0,3 m |
Protection class sensor acc. to DIN EN 61140 | Class III |
Mounting screw | M5 with hexagon socket |
Weight | See table |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
When the valve is not actuated, the sensor sends a signal through pin 4 of the sensor connection. When the valve is actuated, the sensor does not send a signal through pin 4 of the sensor connection. The valve with position detection is possible to be used in categories 3 and 4 according to ISO 13849 in order to reach a Performance Level (PL) of the control system up to PL = e. On its own, the valve with position detection is not a safety component and is not a complete safety solution. It is designed to increase the diagnostic coverage (DC) of the control system. For use in categories 3 to 4, additional requirements of DIN EN ISO 13849-1:2008-12 (e.g. CCF, DC, PLr, software, systematic errors) are taken into consideration by the user. |
Housing | Polyamide Aluminum |
Seals | Acrylonitrile butadiene rubber |