Standardization | ISO 5599-1 |
Frame size | ISO 3 |
Switching principle | 5/2 |
Version | Poppet valve |
Housing | Aluminum |
Sealing material | Acrylonitrile butadiene rubber |
Protection class | IP65 |
Port size | EN 175301-803, form A |
Type | Plug |
Nominal flow Qn | 4300 l/min |
Operational voltage AC at 50 Hz | 110 V |
Operational voltage AC at 60 Hz | 110 V |
DC operating voltage | 110 V |
Activation | Electrically |
Version | Poppet valve |
Activation | Electrically |
Pilot | Internal |
Sealing principle | Soft sealing |
Blocking principle | Single base plate principle |
Standards | ISO 5599-1, ISO 3 |
Working pressure min./max. | 3,5 … 9 bar |
Control pressure min./max. | 3,5 … 9 bar |
Ambient temperature min./max. | 10 … 120 °C |
Medium temperature min./max. | 10 … 120 °C |
Medium | Compressed air |
Max. particle size | 50 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow Qn | 4300 l/min |
Protection class with connection | IP65 |
Duty cycle | 100 % |
Typ. switch-on time | 50 ms |
Typ. switch-off time | 80 ms |
Mounting screw tightening torque | 11 Nm |
Weight | 1,73 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Max. ambient temperature: +180 °C at 1 hour continuous operation and up to +200 °C at 15 hours standby operation At an ambient temperature of over 120 °C , the duty cycle is reduced by 50%. Scope of delivery: incl. valve plug connector and pilot valve |
Material |
---|
Housing | Aluminum |
Seals | Acrylonitrile butadiene rubber |