| Actuating control | double solenoid |
| Switching principle | 5/2 |
| Housing | Polyamide fiber-glass reinforced |
| Sealing material | Acrylonitrile butadiene rubber |
| Protection class | IP65 |
| Number of wires | 3-pin |
| Port size | M8x1 |
| Nominal flow Qn | 610 l/min |
| Compressed air connection input | Ø 3/8 |
| Compressed air connection output | Ø 3/8 |
| DC operating voltage | 24 V |
| Activation | Electrically |
| Activation | Electrically |
| Working pressure min./max. | 3 … 8 bar |
| Ambient temperature min./max. | 5 … 50 °C |
| Medium temperature min./max. | 5 … 50 °C |
| Medium | Compressed air |
| Max. particle size | 40 µm |
| Oil content of compressed air | 0 … 5 mg/m³ |
| Nominal flow Qn | 610 l/min |
| Protection class with connection | IP65 |
| Duty cycle | 100 % |
| The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Exhaust air throttling may only be used in operating lines |
| Material |
|---|
| Housing | Polyamide fiber-glass reinforced |
| Seals | Acrylonitrile butadiene rubber |