Standardization | ISO 5599-1 |
Frame size | ISO 4 |
Return type | With air spring return |
Switching principle | 5/2 |
Version | Spool valve |
Housing | Aluminum |
Sealing material | Acrylonitrile butadiene rubber |
Protection class | IP65 |
Port size | Form B, industry |
Type | Plug |
Nominal flow Qn | 6000 l/min |
Compressed air connection input | Base plate ISO 5599-1 |
Compressed air connection output | Base plate ISO 5599-1 |
Operational voltage AC at 50 Hz | 24 V |
Version | Spool valve |
Sealing principle | Soft sealing |
Blocking principle | Single base plate principle |
Connection type | Plate connection |
Standards | ISO 5599-1, ISO 4 |
Working pressure min./max. | See table |
Control pressure min./max. | 1,5 … 10 bar |
Ambient temperature min./max. | -15 … 50 °C |
Medium temperature min./max. | -15 … 50 °C |
Medium | Compressed air |
Max. particle size | 50 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow Qn | 6000 l/min |
Flow conductance C | 24,5 l/(s*bar) |
Protection class with connection | IP65 |
Duty cycle | 100 % |
Typ. switch-on time | 23 ms |
Typ. switch-off time | 64 ms |
Mounting screw | with hexagon socket |
Mounting screw tightening torque | 10 Nm |
Weight | 1,36 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Housing | Aluminum |
Seals | Acrylonitrile butadiene rubber |