Version | Poppet valve |
Housing | Polyamide |
Sealing material | Acrylonitrile butadiene rubber,Polyurethane |
Protection class | IP65 |
Port size | ISO 15217, form C |
Type | Plug |
Nominal flow Qn | 600 l/min |
Compressed air connection output | Ø 8×1 |
DC operating voltage | 12 V |
Activation | Electrically |
Version | Poppet valve |
Activation | Electrically |
Pilot | Internal |
Sealing principle | Soft sealing |
Working pressure min./max. | 2 … 8 bar |
Ambient temperature min./max. | -15 … 50 °C |
Medium temperature min./max. | -15 … 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 … 1 mg/m³ |
Nominal flow Qn | 600 l/min |
Protection class with connection | IP65 |
Reverse polarity protection | Protected against polarity reversal |
Duty cycle | 100 % |
Typ. switch-on time | 27 ms |
Typ. switch-off time | 28 ms |
Weight | 0,133 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
At an ambient temperature of 40 °C the max. working pressure is 10 bar . Versions with voltage of less than 50 V DC do not have a protective ground. |
Material |
---|
Housing | Polyamide |
Seals | Acrylonitrile butadiene rubber Polyurethane |