Actuating control | single solenoid |
Return type | With spring return |
Switching principle | 3/2 |
Version | Spool valve |
Housing | Stainless steel |
Sealing material | Acrylonitrile butadiene rubber |
Protection class | IP65 |
Port size | ISO 15217, form C |
Type | Plug |
Nominal flow Qn | 280 l/min |
Compressed air connection input | G 1/8 |
Compressed air connection output | G 1/8 |
DC operating voltage | 24 V |
Activation | Electrically |
Version | Spool valve |
Activation | Electrically |
Pilot | Internal |
Sealing principle | metal/metal sealing |
Working pressure min./max. | 2 … 10 bar |
Control pressure min./max. | 2 … 10 bar |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 5 … 25 mg/m³ |
Nominal flow Qn | 280 l/min |
Protection class with connection | IP65 |
Duty cycle | 100 % |
mounting screws | M4 with hexagon socket |
Mounting screw tightening torque | 2,5 Nm |
Tightening torque tolerance | ±0,5 |
Weight | 0,22 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Notice: This product may only be operated with oiled compressed air. |
Material |
---|
Housing | Stainless steel, hardened |
Seals | Acrylonitrile butadiene rubber |
Front plate | Aluminum, hard-anodized |
End plate | Polyamide |