Return type | With spring return |
Switching principle | 3/2 |
Version | Poppet valve |
Housing | Polyamide |
Sealing material | Fluorocaoutchouc |
Protection class | IP65 |
Port size | ISO 6952, form B |
Type | Plug |
Qn 1?2 | 55 l/min |
Qn 2?3 | 80 l/min |
Compressed air connection input | G 1/8 |
Compressed air connection output | G 1/8 |
DC operating voltage | 24 V |
Activation | Electrically |
Version | Poppet valve |
Activation | Electrically |
Sealing principle | Soft sealing |
Working pressure min./max. | See table |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow 1 ? 2 | See table |
Nominal flow 2 ? 3 | See table |
Protection class with connection | IP65 |
Compatibility index | See table |
Duty cycle | 100 % |
mounting screws | M4 |
Weight | 0,11 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | Polyamide |
Seals | Fluorocaoutchouc |