Return type | With spring return |
Switching principle | 3/2 |
Version | Poppet valve |
Housing | polyphenylene sulfide,Polyamide fiber-glass reinforced |
Sealing material | Acrylonitrile butadiene rubber |
Protection class | IP65 |
Port size | ISO 15217, form C |
Type | Plug |
Qn 1?2 | 25 l/min |
Qn 2?3 | 36 l/min |
Operational voltage AC at 60 Hz | 110 V |
Activation | Electrically |
Version | Poppet valve |
Activation | Electrically |
Sealing principle | Soft sealing |
Working pressure min./max. | See table |
Ambient temperature min./max. | -10 … 50 °C |
Medium temperature min./max. | -10 … 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow 1 ? 2 | See table |
Nominal flow 2 ? 3 | See table |
Protection class acc. to DIN EN 61140 Electrically | Class I |
Protection class with connection | IP65 |
Duty cycle | 100 % |
Mounting on manifold strip | PRS strip |
mounting screws | M3 |
Weight | 0,035 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | polyphenylene sulfide Polyamide fiber-glass reinforced |
Seals | Acrylonitrile butadiene rubber |