Actuating control | single solenoid |
Return type | With spring return |
Switching principle | 3/2 |
Version | Spool valve, positive overlapping |
Housing | Aluminum,Polyamide fiber-glass reinforced |
Sealing material | Acrylonitrile butadiene rubber,Polyurethane |
Connector standard | EN 175301-803:2006 |
Protection class | IP65 |
Number of wires | 3-pin |
Port size | EN 175301-803, form A |
Type | Plug |
Qn 1?2 | 4000 l/min |
Qn 2?3 | 4000 l/min |
Nominal flow Qn | 4000 l/min |
Compressed air connection input | G 1/2 |
Compressed air connection output | G 1/2 |
Operational voltage AC at 50 Hz | 110 V |
Operational voltage AC at 60 Hz | 110 V |
Activation | Electrically |
Temperature resistance | -25 °C cold-resistant |
Version | Spool valve, positive overlapping |
Activation | Electrically |
Sealing principle | Soft sealing |
Working pressure min./max. | See table |
Control pressure min./max. | See table |
Ambient temperature min./max. | See table |
Medium temperature min./max. | See table |
Medium | Compressed air |
Max. particle size | 50 µm |
Oil content of compressed air | 0 … 1 mg/m³ |
Nominal flow Qn | 4000 l/min |
Nominal flow 1 ? 2 | 4000 l/min |
Nominal flow 2 ? 3 | 4000 l/min |
Compressed air connection | according to ISO 228-1 |
Pilot control exhaust | with directional pilot air exhaust |
Connector standard | EN 175301-803:2006 |
Reverse polarity protection | Protected against polarity reversal |
Compatibility index | See table |
Duty cycle | 100 % |
Weight | See table |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coils catalog page. option valve: The input and output compressed air connections can be exchanged.The valve can thereby be used in the NC or NO operating mode. *Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximum working pressure is 10 bar. |
Material |
---|
Housing | Aluminum Polyamide fiber-glass reinforced |
Seals | Acrylonitrile butadiene rubber Polyurethane |