Switching principle | 3/2 |
Version | Poppet valve |
Housing | Aluminum |
Sealing material | Acrylonitrile butadiene rubber |
Protection class | IP65 |
Port size | Form B, industry |
Type | Plug |
Nominal flow Qn | 1350 l/min |
Compressed air connection input | G 1/4 |
Operational voltage AC at 50 Hz | 230 V |
Activation | Electrically |
Version | Poppet valve |
Activation | Electrically |
Working pressure min./max. | 3,5 … 10 bar |
Control pressure min./max. | 3,5 … 10 bar |
Ambient temperature min./max. | -20 … 50 °C |
Medium temperature min./max. | -20 … 50 °C |
Medium | Compressed air |
Max. particle size | 5 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow Qn | 1350 l/min |
Duty cycle | 100 % |
Weight | 0,38 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Min./max. operating pressure for external pilot: – 1 bar / 10 bar The valves can be energized via the port closed with a plug on the front side of the cover. |
Material |
---|
Housing | Aluminum |