| Version | Poppet valve |
| Housing | Die cast zinc |
| Sealing material | Acrylonitrile butadiene styrene |
| Connector standard | ISO 6952 |
| Protection class | IP65 |
| Port size | ISO 6952, form B |
| Type | Plug |
| Qn 1?2 | 4000 l/min |
| Qn 2?3 | 1600 l/min |
| Compressed air connection input | G 1/2 |
| Compressed air connection output | G 1/2 |
| Operational voltage AC at 50 Hz | 230 V |
| Operational voltage AC at 60 Hz | 230 V |
| Version | Poppet valve, Can be assembled into blocks |
| Parts | 3/2-directional valve, electrically operated |
| Nominal flow 1 ? 2 | 4000 l/min |
| Nominal flow 2 ? 3 | 1600 l/min |
| Working pressure min./max. | 2,5 … 10 bar |
| Medium | Compressed air Neutral gases |
| Medium temperature min./max. | -10 … 60 °C |
| Ambient temperature min./max. | -10 … 60 °C |
| Pilot | Internal |
| Sealing principle | Soft sealing |
| Max. particle size | 5 µm |
| Protection class acc. to DIN EN 61140 with plug | IP65 |
| Duty cycle | 100 % |
| Weight | See table |
| The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . ATEX optional: The ATEX ID depends on the selected ATEX coil. A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about the vertical axis. Please see the operating instructions for further details. |
| Material |
|---|
| Housing | Die cast zinc |
| Front plate | Acrylonitrile butadiene styrene |
| Seals | Acrylonitrile butadiene styrene |