Version | Poppet valve |
Housing | Polyamide |
Sealing material | Acrylonitrile butadiene rubber |
Protection class | IP65 |
Port size | ISO 15217, form C |
Type | Plug |
Qn 1?2 | 12500 l/min |
Qn 2?3 | 3700 l/min |
Nominal flow Qn | 12500 l/min |
Compressed air connection input | G 1 |
Compressed air connection output | G 1 |
DC operating voltage | 24 V |
Version | Poppet valve, Can be assembled into blocks |
Parts | 3/2-directional valve, electrically operated |
Nominal flow | 12500 l/min |
Nominal flow 1 ? 2 | 12500 l/min |
Nominal flow 2 ? 3 | 3700 l/min |
Working pressure min./max. | 2,5 … 10 bar |
Medium | Compressed air Neutral gases |
Medium temperature min./max. | -10 … 50 °C |
Ambient temperature min./max. | -10 … 50 °C |
Sealing principle | Soft sealing |
Max. particle size | 25 µm |
Protection class acc. to DIN EN 61140 with plug | IP65 |
Weight | 0,459 kg |
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180° about the vertical axis. Please see the operating instructions for further details. The sensor signal is visible on the front of the cover. Electronic sensor R412003658 included in scope of delivery (assembled). For sensor connection, see the selection table. An ST6 sensor (contactless) is used to detect the switching position in the non-actuated state (position: exhaust). |
Material |
---|
Housing | Polyamide |
Front plate | Acrylonitrile butadiene styrene |
Seals | Acrylonitrile butadiene rubber |
Threaded bushing | Die cast zinc |