Actuating control | double solenoid |
Return type | With spring return |
Switching principle | 2×2/2 |
Version | Spool valve, positive overlapping |
Housing | Polyamide fiber-glass reinforced |
Sealing material | Acrylonitrile butadiene rubber,Hydrogenated acrylonitrile butadiene rubber |
Protection class | IP65 |
Nominal flow Qn | 280 l/min |
DC operating voltage | 24 V |
Activation | Electrically |
Version | Spool valve, positive overlapping |
Activation | Electrically |
Pilot | External |
Sealing principle | Soft sealing |
Blocking principle | Base plate principle, multiple |
Working pressure min./max. | -0,9 … 10 bar |
Control pressure min./max. | 3 … 8 bar |
Ambient temperature min./max. | -10 … 60 °C |
Medium temperature min./max. | -10 … 60 °C |
Medium | Compressed air |
Max. particle size | 40 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow Qn | 280 l/min |
Pilot control exhaust | with directional pilot air exhaust |
Protection class with connection | IP65 |
Protective circuit | Z-diode |
Reverse polarity protection | Protected against polarity reversal |
LED status display | Yellow |
Duty cycle | 100 % |
Typ. switch-on time | 16 ms |
Typ. switch-off time | 20 ms |
mounting screws | Hexalobular socket (TORX) ISO 10664-8 |
Mounting screw tightening torque | 0,52 Nm |
Weight | 0,052 kg |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | Polyamide fiber-glass reinforced |
Seals | Acrylonitrile butadiene rubber Hydrogenated acrylonitrile butadiene rubber |
Front plate | Polyamide fiber-glass reinforced |
End plate | Polyamide |