Actuating control | single solenoid |
Return type | With spring return |
Switching principle | 2×3/2 |
Housing | Polyamide,Polyoxymethylene |
Sealing material | Acrylonitrile butadiene rubber |
Nominal flow Qn | 500 l/min |
Compressed air connection input | Base plate |
Compressed air connection output | Ø 8 |
Activation | Electrically |
Activation | Electrically |
Working pressure min./max. | -0,8 … 8 bar |
Control pressure min./max. | 3 … 8 bar |
Ambient temperature min./max. | 5 … 50 °C |
Medium temperature min./max. | 5 … 50 °C |
Medium | Compressed air |
Max. particle size | 40 µm |
Oil content of compressed air | 0 … 5 mg/m³ |
Nominal flow Qn | See table |
mounting screws | Hexalobular socket (TORX) ISO 10664-10 |
Mounting screw tightening torque | 0,9 Nm |
Tightening torque tolerance | ±0,1 mT |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
Material |
---|
Housing | Polyamide Polyoxymethylene |
Seals | Acrylonitrile butadiene rubber |